BYCRT - KAVO QUICK SPRAY
- MSDS: BYCRT
- Manufacturer: IKAVO DENTALE MEDIZINISCHE
- Product Name: KAVO QUICK SPRAY
- National Stock Number: 6520-01-379-9034
Product Identification
Product ID:KAVO QUICK SPRAY
MSDS Date:05/15/1986
FSC:6520
NIIN:01-379-9034
MSDS Number: BYCRT
Responsible Party
BISMARCKRING 39 POSTFACH 1454,GERMANY
US
Emergency Phone: 312-885-3855
Info Phone: 312-885-3855
Cage: NO560
Contractor
Telephone: 708-550-6800
Cage: D0357
Ingredients
FREON F 11 A (FLUOROTRICHLOROMETHANE)
Fraction By Weight: 188.4% G
PROPANE
CAS: 74-98-6
RTECS: TX2275000
Fraction By Weight: 62.8% G
OSHA PEL 1000 PPM
ACGIH TLV: ASPHYXIANT; 9495
BUTANE
CAS: 106-97-8
RTECS: EJ4200000
Fraction By Weight: 3.5% G
OSHA PEL 800 PPM
ACGIH TLV: 800 PPM; 9495
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NO DANGER UNDER NORMAL USAGE. FREON F
11 A:LONG TERM EXPOSURE/ACCIDENTS:FROSTBITE. PROPANE/BUTANE:LONG
TERM INHAL AFFECTS RESPIRATION.
Effects of Overexposure:NUMBNESS, TICKLING & ITCHING, POSSIBLE
STIFFNESS. DIZZINESS, DISORIENTATION, EXCITATION, FROSTBITE.
Medical Cond Aggravated by Exposure:NONE KNOWN.
First Aid
First Aid:REWARM AFFECTED AREA, SEEK PROFESSIONAL HELP. VENTILATION,
ARTIFICIAL RESPIRATION. FOR FROSTBITE:REWARM AFFECTED ARM, SEEEK
PROFESSIONAL HELP.
Fire Fighting
Flash Point:-112F,-80C GAS
Lower Limits:1.5 GAS
Upper Limits:8.4 GAS
Extinguishing Media:O2, FOAM EXTINGUISHER, POWDER EXTINGUISHER
CLASSIFICATION A-O.
Fire Fighting Procedures:SAME MEASURES AS FOR PROPANE/BUTANE.
Accidental Release
Spill Release Procedures:GENERALLY VENTILATE AREA, USE STANDARD OIL
DRYING COMPOUND FOR SPILLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:PROTECT FROM SUNLIGHT.DO NOT EXPOSE TO
TEMP EXCEEDING 50C.DO NOT PIERCE OR BURN,EVEN AFTER USE.DO NOT
SPRAY ON NAKED FLAME OR ANY INCANDESCENT MATL.
Other Precautions:DO NOT INCINERATE CAN.
Exposure Controls
Respiratory Protection:NOT NEEDED UNDER NORMAL USE.
Ventilation:LOCAL EXHAU VENTI:NONE NEEDED. MECH (GEN):LOCAL CODE
ACCEPTED BUILDING VENTILATION.
Protective Gloves:NONE NEEDED UNDER NORMAL USAGE.
Eye Protection:NOT NEEDED.
Other Protective Equipment:NONE NEEDED.
Work Hygienic Practices:WASH HANDS AFTER HANLDING.
Supplemental Safety and Health
Chemical Properties
HCC:V3
Boiling Pt:B.P. Text:31.1F,-0.5C
Vapor Pres:900 @0C
Vapor Density:0.548 @20C
Spec Gravity:1.045
Evaporation Rate & Reference:168 GAS, BUTYL ACETATE=1
Solubility in Water:NO.
Appearance and Odor:CLEAR, ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:THERE ARE NONE.
Disposal
Waste Disposal Methods:SAME AS FOR WASTE OIL, DO NOT MIX WITH ACIDS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.